BS EN 50131 explained

Intruder alarm system grades explained

Most insurers specify a minimum alarm grade in your policy documents - check yours before installing or upgrading a system. Below, AMCO explains what grades 1-4 mean, what a true Grade 3 system actually requires, and how it's maintained.

SSAIB Accredited100% Insurance Compliant24/7 Alarm Receiving CentreFamily-Run UK CompanyPolice Response EscalationUK-Based Support TeamSSAIB Accredited100% Insurance Compliant24/7 Alarm Receiving CentreFamily-Run UK CompanyPolice Response EscalationUK-Based Support Team
The basics

What are the alarm grades?

BS EN 50131 defines four grades of intruder alarm system, based on the level of skill and equipment an intruder is assumed to have. The higher the grade, the more resilient the system needs to be.

GradeRisk levelDescription
Grade 1Low riskIntruders assumed to have limited knowledge of alarm systems and only basic tools.
Grade 2Low-medium riskSome knowledge of alarm systems and a range of tools.Typically qualifies for police response
Grade 3Medium-high riskFull knowledge of alarm systems and a comprehensive range of tools.Typically qualifies for police response
Grade 4High riskIntruders with the ability to plan an intrusion in detail and access to a full range of equipment.Rarely used in practice

Only Grade 2 and Grade 3 systems typically qualify for police response. Grade 4 is rarely used outside very high-risk commercial sites.

The single most important rule

A system's overall grade defaults to the lowest grade of any component fitted. One Grade 2 wireless sensor added to an otherwise Grade 3 system pulls the whole installation down to Grade 2 - so every part of the system needs to be specified and installed consistently.

Not sure what grade you need?

Check your insurance documentation, or ask AMCO to confirm the right grade for your property.

Upgrading

How to upgrade to Grade 3

A true Grade 3 system isn't just a different setting on the panel - every component needs to be rated and installed to Grade 3 requirements.

Grade 3 alarm panel

A metal enclosure with back-tamper protection - not the plastic casing found on most Grade 2 panels.

Grade 3 sensors

Wired, with both front and back tamper protection plus anti-masking detection, so a sensor can't be blocked or covered without triggering an alert.

No wireless equipment

A true Grade 3 system is wired throughout. Most wireless sensors on the market are only Grade 2 rated.

Grade 3 external bell box

Rated to Grade 3, with multiple tamper switches to detect any attempt to remove or disable it.

Correctly rated signalling

Monitoring/signalling equipment rated to DP3 or DP4, matching the rest of the system.

Reference

British Standards referenced

Alarm grading draws on several British and European standards - here's what each one actually covers.

BS 4737

The former UK standard, withdrawn in 2004.

PD 6662:2017

The UK's adoption of the current European standards.

BS 9263

System maintenance requirements.

BS 8243:2010

Confirmed-activation systems, used for police response.

BS EN 50131

General intruder alarm system requirements.

BS EN 50136

Alarm signalling and transmission systems.

SS 2004

The SSAIB code of practice for temporary systems.

Signalling

Alarm signalling & monitoring types

The signalling path is how your alarm reports an activation to a monitoring centre. Its grade needs to match the rest of your system.

Legacy

Redcare (BT)

A legacy single-path signalling service that ran over the phone line. BT has now closed this service, so customers previously on Redcare have moved to DualCom or LiveTalk.

Dual-path

DualCom (CSL)

A dual-path signalling device using both the phone line and the mobile network as backup. Available at Grade 2, 3 or 4, depending on how frequently it polls to confirm it's still working.

AMCO's own

LiveTalk (AMCO)

AMCO's own audio-confirmation monitoring technology. An operator listens and talks into the property to confirm a genuine break-in, which speeds up the police response.

More about LiveTalk

AMCO's monitored alarms are built around LiveTalk - read more about how LiveTalk works or see our full guide to monitored alarms.

Ongoing compliance

Maintenance & fault-reporting requirements

Higher grades require more frequent maintenance visits, and faster reporting of any fault on the signalling path.

Maintenance visits required

GradeRequirement
Grade 21 annual site visit
Grade 2 & 32 annual visits, or 1 site visit plus 1 remote check
Grade 42 annual site visits

Time to report a fault

GradeTime to report
Grade 224 hours
Grade 31 hour
Grade 43 minutes
Why AMCO

A Grade 3 specialist installer

AMCO has fitted and maintained graded intruder alarm systems for over 25 years, from standard Grade 2 domestic installs to full Grade 3 systems for high-risk commercial sites. Our engineers know exactly which panels, sensors and signalling equipment keep a system's grade consistent throughout.

Read more about our Texecom installation expertise or see our business security services.

Why customers choose AMCO

  • Grade 3 specialist installer, NSI & SSAIB approved
  • 25+ years fitting and maintaining graded alarm systems
  • UK-wide coverage, from single sites to multi-site estates
NSI & SSAIB
Family-run

Need a Grade 3 system surveyed?

AMCO can assess your current setup and confirm exactly what's needed to reach - and keep - Grade 3.

Insurer expectations

What insurers expect from a graded system

Common questions about how alarm grades, approval bodies and keyholder protocols affect your insurance cover.

It depends on the property and how the system is used. As a rough guide, audible-only systems are usually rated Grade 2E, monitored domestic systems are typically Grade 2, and monitored commercial systems are usually expected to be Grade 3.

Your policy documents will state the exact grade required - check these before installing or upgrading a system, or see our insurance specifications page for AMCO's own compliance detail.

Most UK insurers will only accept a graded system if it's installed and maintained by an NSI or SSAIB-approved company. AMCO is SSAIB registered, so our installations and Certificates of Conformity are recognised by insurers as standard.
DP stands for 'Digital Communicator Protocol' and describes how quickly a signalling path is required to report a fault - broadly, DP2 systems allow longer fault-reporting windows and DP3/DP4 require much faster reporting. Higher-grade systems need signalling equipment rated to match, so a Grade 3 panel needs DP3 (or better) signalling to keep its overall grade.
Keyholders should be registered with the monitoring centre in advance. Best practice - and often an insurer requirement - is to nominate at least two responders, who meet off-site before attending the property together, rather than a single keyholder approaching an active alarm alone.

Free, no-obligation

Ready to check your alarm's grade?

Whether you need a standard Grade 2 install or a full Grade 3 specification, see our insurance specifications or get in touch and we'll advise on the right system for your policy.

Free, no-obligation quote

Get your free AMCO security quote

Tell us a little about what you'd like to protect and a member of our family-run team will be in touch - no pressure, no jargon.

  • Most quotes sorted in minutes by phone
  • SSAIB accredited · 100% insurance compliant
  • Spring offer: up to £100 off installation

Covering England, Scotland & Wales

Home
Monitored alarm (LiveTalk)

No obligation. We'll never share your details.