Free, no-obligation quotes - most done in under 10 minutes
Call AMCO free · 0800 13 03 999
UK home protected by AMCO
Insurance specifications

Insurance policy specifications for AMCO alarm systems

The detail and specifications around the insurance compliance and compatibility of AMCO alarm systems - use these when answering questions from your insurance company.

ComplianceAt a glance
SSAIB registered ARC
Grade 2 standard install
Type B police response

Cat II

ARC grade

L1/L2

Police response

PD 6662

Standard

SSAIB Accredited100% Insurance Compliant24/7 Alarm Receiving CentreFamily-Run UK CompanyPolice Response EscalationUK-Based Support TeamSSAIB Accredited100% Insurance Compliant24/7 Alarm Receiving CentreFamily-Run UK CompanyPolice Response EscalationUK-Based Support Team
Why it matters

Non-compliant alarms can invalidate a claim

Most UK insurers require your alarm system to be installed and monitored to specific standards - SSAIB or NSI accreditation, a minimum equipment grade, and a recognised police response type. If your system falls short, a claim can be delayed or refused.

AMCO systems are designed to meet these requirements from day one, and we supply the documentation your insurer will ask to see - so compliance is never something you have to chase up later.

AMCO engineer completing a compliance check

Certificate of Conformity supplied with every installation.

Not sure if your alarm is compliant?

We can review your current setup and confirm what's needed to satisfy your insurer.

Compliance, covered

The pillars of an insurance-compliant alarm

SSAIB accreditation

Our monitoring centre is SSAIB registered, meeting the strict standards most insurers require.

LiveTalk verification

Audio verification means fewer false alarms - and faster, more confident police response.

Grade 2 (& 3) systems

Installed to British Standard PD 6662 - Grade 2 as standard, Grade 3 available for high-risk sites.

Type B police response

LiveTalk verification means no URN is needed - police respond based on verified evidence.

Scheduled maintenance

Remote connection checks, on-site visits and battery changes keep your system compliant.

Certificate of Conformity

Supplied with every installation - the documentation your insurer will ask for.

Full specification detail

Everything your insurer needs to know

Use the answers below when confirming AMCO's specifications with your insurance company.

AMCO's LiveTalk alarm monitoring system is based around 'audio verification'. Using the LiveTalk speaker / microphone units that are installed, our monitoring staff can actively listen and talk into a property:

- Verification: listening allows us to 'verify' an intrusion / attack / fire incident is in progress.

- Deterrence: talking allows us to speak to the persons inside the property and either scare them off (if they're intruders) or verify they're a legitimate person via asking them for their pre-arranged password.

In the instance of a 'verified' (confirmed) incident (intrusion / attack / fire) our monitoring staff will react by immediately calling the relevant emergency service i.e. police, fire brigade or ambulance.

It is the high level of remote verification (via our LiveTalk speaker / microphone unit) that makes AMCO's monitored alarm systems the most effective on the market: robust in our ability to verify and respond to an incident, as well as limiting the number of false alarm responses by the emergency services (i.e. we only call the police in instances of a verified activity).

AMCO's LiveTalk system connects to all forms of 'emergency scenario', including intruder, fire and medical. LiveTalk provides the highest possible response to an emergency scenario, limiting potential loss for insurance companies.

- Intruder: connecting LiveTalk monitoring is the most standard form of monitoring, meaning that whenever an intruder is detected by your alarm system, LiveTalk will be activated and the police will be informed.

- Fire: it's easy to connect LiveTalk to your smoke alarms / fire system. This means we can immediately call the fire brigade in a verified fire situation. AMCO have saved multiple properties over the years with this fire monitoring service.

- Medical: if you connect 'panic buttons' to LiveTalk we can immediately call the ambulance service in the case of a medical emergency (once the panic button has been pressed). AMCO have saved multiple lives throughout the years via this service.

- Landline / PSTN: this is the standard way to connect an alarm system to the monitoring station. PSTN (standard telephone lines) are regarded as the most robust / reliable.

- Mobile / GSM: using a GSM unit is a good channel for locations without fixed landlines, or as use as a 'back-up' to a landline (in case of failure or line-cut).

- Internet / VOIP: an option for properties without a PSTN line. N.B. Systems connected via the internet should also include battery-back up systems to your properties router, as in the case of power failure your system will be redundant.

Yes. AMCO Security's monitoring centre is SSAIB registered meaning that it adheres to the strict regulations and processes set-up by SSAIB, a UK-based security certification organisation.

AMCO monitored alarms provide both level 1 and level 2 police response, depending on the type of incident verified by our monitoring staff.

Types of incident and associated police response levels are as follows:

- Verified violent personal attack in progress: Level 1

- Verified violent Burglary in progress: Level 1

- Verified passive Burglary (i.e. burglars no longer on site after being scared off by verbal warning via LiveTalk monitoring staff): Level 2

- Verified passive attack (i.e. personal attack is no longer in process / ended after verbal warning via LiveTalk monitoring staff): Level 2

- Non-verified activity on site (i.e. LiveTalk monitoring staff can't hear / verify any activity on site): Level 3

- Level 1: immediate response (subject to police priorities)

- Level 2: desirable response but dependent on police resource

- Level 3: no police response (key holder only)

NPCC (National Police Chiefs Council) Unified Intruder Alarm Policy is used by the police across the UK, in which two types of burglar alarm are specified along with relevant police response:

- Type A: reliant on a URN number

- Type B: reliant on evidence / witnesses of an offence in progress

AMCO monitored alarm systems by following the Type B procedure, as our LiveTalk system enables our monitoring staff to verify whether an offence is in progress and call the police. As AMCO follow Type B procedure and all activities are 'verified' our systems are not issued with a police URN (Unique Reference Number).

N.B. police response in both Type A and Type B cases is dependent on the available police resources and competing emergency calls.

There are x4 different 'grades' of security system, all of which are based around levels of resilience of the alarm system to attacks by intruders or outside influences (level 1 being the least secure and level 4 the most secure).

- Grade 1: lowest grade, with only basic provision for component quality / resilience.

- Grade 2: standard level of equipment resilience. Good for home or non-high risk business use (e.g. high street shops / offices).

- Grade 3: high level of equipment resilience including 'anti-masking' technology on sensors, to prevent them for being covered up / tampered with. Good for high-risk businesses (e.g. banks).

- Grade 4: highest level of equipment resilience.

As standard, AMCO install systems that adhere to Grade 2 specifications. Where required AMCO can also install Grade 3 systems. AMCO do not as standard install Grade 4.

AMCO provide a number of different 'remote' and 'on site' system checks and system maintenance services:

- Monthly remote system 'connection checks'

- 12 / 24 month system on-site maintenance checks (these onsite visits are at the request of the customer, and not mandated - unless specified by your insurance company)

- 4 yearly battery change visit

Read more about AMCO's maintenance and servicing procedures, via our maintenance policy page here »

Free, no-obligation quote

Get your free AMCO security quote

Tell us a little about what you'd like to protect and a member of our family-run team will be in touch - no pressure, no jargon.

  • Most quotes sorted in minutes by phone
  • SSAIB accredited · 100% insurance compliant
  • Spring offer: up to £100 off installation

Covering England, Scotland & Wales

Home
Monitored alarm (LiveTalk)

No obligation. We'll never share your details.

SSAIB registered & 100% insurance compliant

Category II Alarm Receiving Centre

A Certificate of Conformity is supplied with every AMCO installation, ready for your insurer.