Insurance approved alarm specifications explained
What an insurer typically expects from an alarm at a standard and a high security level, the four things they look for, and a plain-English glossary of the standards and jargon in your policy documents.
Looking for AMCO’s own compliance answers to give your insurer? See our insurance policy specifications.
What’s typically required at each security level
Your policy documents state the exact requirement, but insurers generally work to one of two levels.
Standard security level
A typical home or a non-high-risk business
- Installer
- SSAIB-certified installer, installing to BS 8243
- Equipment
- Grade 2 equipment
- Monitoring
- Monitored to BS 5979
- Maintenance
- A maintenance contract to BS 9263
High security level
Higher-risk premises, where the policy asks for more
- Installer
- SSAIB certification, with installation to BS 8243
- Equipment
- Grade 3 equipment
- Monitoring
- Monitored to BS 5979
- Police response
- Level 1 Police Response, with a Unique Reference Number (URN)
Not sure what each grade actually means? Our alarm grades guide has the full breakdown, and the British Standards page goes deeper on the technical detail.
Not sure which level your policy needs?
Send us your policy wording and we'll confirm what your alarm needs to meet it.
Four things insurers look for
1 of 4
UKAS-accredited installation
The alarm is installed by a company certified by an accredited body - NSI or SSAIB - rather than an uncertified installer.
2 of 4
Equipment installed to PD 6662
Detection circuits and external audible devices (the bell box or sounder) fitted to the standard that adopts the current European rules in the UK.
3 of 4
Modern alarm signalling
Dual-path (DP3-compliant) signalling, so the alarm can still reach the monitoring centre if one path fails.
4 of 4
Police response set up correctly
Police response arranged with confirmed-activation protocols, so a genuine activation is eligible for a police response.
Which signalling options meet the requirement today
For the “modern dual-path” requirement, the current options AMCO fits are CSL DualCom and AMCO LiveTalk in its dual-path configuration. Both use two independent paths, typically internet plus mobile (GSM), so a single failure doesn’t cut your alarm off from the monitoring centre.
- Dual-path signalling, rated to match the grade of the rest of the system
- Monitored by an SSAIB-registered alarm receiving centre
- Certificate of Conformity supplied with every installation
A note on BT Redcare
BT closed its Redcare signalling service on 15 December 2025, so it is no longer an option. If your alarm still has a Redcare communicator, it may no longer be reaching a monitoring centre - which could matter to your insurer.
How to switch from analogue to IPThe jargon in your policy, explained
Short definitions of the bodies, standards and terms insurers commonly refer to.
A Unique Reference Number. Under a Type A police response, the URN is what identifies your alarm to the police. It is tied to your alarm receiving centre and signalling setup, so it is worth confirming it has carried across whenever your monitoring or communicator changes.
AMCO’s LiveTalk verification works on the Type B procedure, where the monitoring team confirms an offence in progress, so no URN is issued. See AMCO’s insurance specifications and our Guide to Police Monitoring.
Level 1: immediate response (subject to police priorities).
Level 2: desirable response, but dependent on police resource.
Level 3: no police response (keyholder only).
Under BS 9263, bells-only systems need one maintenance visit a year, while monitored systems need two. For Grade 2 and Grade 3 monitored systems that can be two site visits, or one site visit plus one remote check. Your insurer may specify its own requirement, so check your policy wording.
See our alarm maintenance service for how AMCO schedules these.
Grades 1 to 4 describe how resilient an alarm system is, based on how skilled and well-equipped an intruder is assumed to be. Grade 2 is the usual standard for a home or non-high-risk business; Grade 3 is used for higher-risk premises. A system’s overall grade defaults to the lowest-graded component fitted.
The full breakdown is on our alarm grades guide.
Related insurance and standards guides
Free, no-obligation
Want your alarm checked against your policy?
Speak to a UK security expert - we’ll tell you what your insurer is likely to want and whether your current system meets it.
Get your free AMCO security quote
Tell us a little about what you'd like to protect and a member of our family-run team will be in touch - no pressure, no jargon.
- Most quotes sorted in minutes by phone
- SSAIB accredited · 100% insurance compliant
- Free, no-obligation quotes